Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 5

413 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 413 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18413 / 413
EER2 · BTU/Wh11.7–13.5413 / 413
HSPF2 · BTU/Wh7.8–8.5413 / 413
Cooling capacity · BTU/h45,500–50,500413 / 413
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500413 / 413
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400413 / 413
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600413 / 413
COP at 5°F / −15°C2.1–2.34413 / 413
Equipment / loop typeHP - Split System413 / 413
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)413 / 413
Compressor stagingTwo-stage413 / 413
Connected capabilityNo413 / 413

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635090017.508.00238002.18EPA 3807557
EVD5X61M21A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 21635105217.508.00238002.16EPA 4000705
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21634968417.008.00232002.18EPA 3803275
EVD5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635113317.008.10250002.14EPA 3803313
EVD5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21635118917.008.10250002.14EPA 3803327
EVD5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635119717.008.10250002.16EPA 3803335
EVD5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635114117.008.10250002.16EPA 3803346
EVD5X48M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635049217.008.00232002.18EPA 3803384
EVM5X49M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634977217.008.10248002.14EPA 3803397
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 21634980417.008.10250002.14EPA 3803421
EVD5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21635054017.008.00240002.16EPA 3803496
EVD5X49M24A*+ furnace: *80VSL0902120B*AHRI reference: 21635054817.008.10250002.12EPA 3803503
EVD5X49M24A*+ furnace: *80VSL1102122B*AHRI reference: 21635055617.008.10250002.14EPA 3803511
EVD5X49M24A*+ furnace: *95MSU1002122A*AHRI reference: 21635065217.008.10248002.16EPA 3803520
EVD5X49M24A*+ furnace: *80VSL1352422B*AHRI reference: 21635056417.008.10250002.14EPA 3803526
EVD5X61M21A*+ furnace: *97VTN0802120A*AHRI reference: 21635124517.008.00250002.10EPA 3803594
EVD5X61M21A*+ furnace: *97VTN1002120A*AHRI reference: 21635125317.008.00250002.12EPA 3803609
EVM5X49M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634987617.008.10252002.12EPA 3803771
EVM5X49M21A*+ furnace: *95MSU1002122A*AHRI reference: 21634988417.008.10248002.16EPA 3803779
EVD5X49M24A*+ furnace: *80VTL0902120B*AHRI reference: 21635058817.008.10250002.12EPA 3803877

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.