Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 2

413 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 413 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18413 / 413
EER2 · BTU/Wh11.7–13.5413 / 413
HSPF2 · BTU/Wh7.8–8.5413 / 413
Cooling capacity · BTU/h45,500–50,500413 / 413
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500413 / 413
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400413 / 413
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600413 / 413
COP at 5°F / −15°C2.1–2.34413 / 413
Equipment / loop typeHP - Split System413 / 413
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)413 / 413
Compressor stagingTwo-stage413 / 413
Connected capabilityNo413 / 413

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635122917.508.00238002.18EPA 3803578 →
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635123717.508.00236002.18EPA 3803586 →
EVD5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 21635126117.508.50246002.28EPA 3803617 →
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 21635057217.508.10246002.16EPA 3803850 →
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 21635135717.508.00236002.18EPA 3803861 →
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635058017.508.00234002.20EPA 3803869 →
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21635066817.508.00234002.18EPA 3803902 →
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21635140517.508.50250002.26EPA 3803954 →
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635141317.508.00236002.18EPA 3803962 →
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21635127717.508.50250002.24EPA 3804011 →
EVD5X61M24A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 21635129317.508.00238002.18EPA 3804092 →
EVM5X49M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21634990017.508.00236002.16EPA 3804171 →
EVM5X49M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21634993217.508.00234002.20EPA 3804206 →
EVD5X49M24A*+WALLCON+ furnace: *97CTN1202422A*AHRI reference: 21635070817.508.00234002.18EPA 3805253 →
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21634994017.508.00236002.16EPA 3805259 →
EVM5X49M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21634995617.508.00236002.16EPA 3805275 →
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21634998817.508.00252002.10EPA 3805407 →
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635002017.508.10244002.16EPA 3805439 →
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635077217.508.00244002.16EPA 3805482 →
EVD5X60M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21635074017.508.00252002.10EPA 3805490 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →