Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 18

413 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 413 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18413 / 413
EER2 · BTU/Wh11.7–13.5413 / 413
HSPF2 · BTU/Wh7.8–8.5413 / 413
Cooling capacity · BTU/h45,500–50,500413 / 413
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500413 / 413
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400413 / 413
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600413 / 413
COP at 5°F / −15°C2.1–2.34413 / 413
Equipment / loop typeHP - Split System413 / 413
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)413 / 413
Compressor stagingTwo-stage413 / 413
Connected capabilityNo413 / 413

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635039616.008.10244002.14EPA 3807290 →
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21635206916.008.10256002.22EPA 3807379 →
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21635230116.008.00254002.22EPA 3807384 →
EVM5X48M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21634967616.008.00234002.16EPA 4000460 →
EA*5X48M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635174916.008.00250002.20EPA 4000499 →
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21635225316.008.00248002.24EPA 4000512 →
EA*5X60M24A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635218116.008.00248002.22EPA 4000550 →
EA*5X60M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21635218916.008.00248002.24EPA 4000558 →
EA*5X61M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635244516.008.00252002.22EPA 4000584 →
EA*5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635166916.008.00250002.22EPA 4000676 →
EA*5X60M24A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21635210116.008.00250002.24EPA 4000713 →
EA*5X60M24A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635210916.008.00248002.22EPA 4000720 →
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635226116.008.00250002.24EPA 4000726 →
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635226916.008.00248002.22EPA 4000735 →
EA*5X61M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21635246916.008.00252002.22EPA 4000769 →
EA*5X60M24A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21635208516.008.00248002.24EPA 4000771 →
EA*5X60M24A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635207716.008.00250002.24EPA 4000813 →
EA*5X48M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635193316.008.00250002.20EPA 4000830 →
EA*5X60M24A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 21635202916.008.00250002.24EPA 4000838 →
EA*5X48M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635182916.008.00250002.20EPA 4000840 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →