Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T36*K*AAA*

Mainline 18 SEER2 HP · source records, page 5

186 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 186 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5186 / 186
EER2 · BTU/Wh11.7–13186 / 186
HSPF2 · BTU/Wh7.8–8.5186 / 186
Cooling capacity · BTU/h33,800–37,600186 / 186
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000186 / 186
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200186 / 186
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600186 / 186
COP at 5°F / −15°C1.84–2.4186 / 186
Equipment / loop typeHP - Split System186 / 186
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)186 / 186
Compressor stagingTwo-stage186 / 186
Connected capabilityNo186 / 186

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635850115.508.10192002.30EPA 3808498
EA*5X37M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635762115.508.00194002.24EPA 3808505
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21635765315.508.00193002.26EPA 3808513
EVD5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635534915.507.80177001.86EPA 3808521
EVD5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635539715.507.80177001.88EPA 3808529
EA*5X43M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635836515.508.00193002.24EPA 3808571
EA*5X43M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635838915.508.10193002.28EPA 3808587
EA*5X43M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635839715.508.10194002.28EPA 3808596
EA*5X43M21A*+ furnace: *95MSU0802120A*AHRI reference: 21635841315.508.10193002.28EPA 3808611
EVD5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635550115.507.80176001.88EPA 3808676
EA*5X37M17A*+ furnace: *80VSL0901716B*AHRI reference: 21635694115.508.10189002.30EPA 3808692
EA*5X37M17A*+ furnace: *80MSU0401712A*AHRI reference: 21635694915.508.10188002.28EPA 3808700
EA*5X37M17A*+ furnace: *80MSU0601716A*AHRI reference: 21635695715.508.10188002.30EPA 3808708
EA*5X42M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635774915.508.10188002.26EPA 3808788
EA*5X43M21A*+ furnace: *95MSU1002120A*AHRI reference: 21635842115.508.10194002.28EPA 3808817
EA*5X43M21A*+ furnace: *96VTN0802120B*AHRI reference: 21635848515.508.10193002.28EPA 3808861
EA*5X43M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635849315.508.10192002.28EPA 3808869
EA*5X43M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21635852515.508.00193002.26EPA 3808880
EA*5X43M21A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21635853315.508.00193002.24EPA 3808888
EA*5X43M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635858115.508.00193002.24EPA 3808912

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →