Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T36*K*AAA*

Mainline 18 SEER2 HP

186 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 186 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5186 / 186
EER2 · BTU/Wh11.7–13186 / 186
HSPF2 · BTU/Wh7.8–8.5186 / 186
Cooling capacity · BTU/h33,800–37,600186 / 186
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000186 / 186
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200186 / 186
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600186 / 186
COP at 5°F / −15°C1.84–2.4186 / 186
Equipment / loop typeHP - Split System186 / 186
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)186 / 186
Compressor stagingTwo-stage186 / 186
Connected capabilityNo186 / 186

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B48L0C*AHRI reference: 21636059716.508.10187002.34EPA 3808443 →
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635447716.007.80175001.86EPA 3805594 →
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635474116.007.80177001.90EPA 3806523 →
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635726116.008.10193002.30EPA 3807803 →
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120A*AHRI reference: 21635815716.008.00193002.26EPA 3807967 →
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635821316.008.10193002.30EPA 3808159 →
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635822116.008.50191002.40EPA 3808189 →
FCMA5B48L0C*+WALLCONAHRI reference: 21636061316.008.00189002.30EPA 3808459 →
EA*5X43M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635854116.008.50192002.40EPA 3808896 →
EVD5X38M17A*+ furnace: *80VSL0901716B*AHRI reference: 21635561316.007.80176001.86EPA 3808928 →
EVD5X38M17A*+ furnace: *80MSU0401712A*AHRI reference: 21635562116.007.80176001.88EPA 3808936 →
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 21635562916.007.80176001.88EPA 3808944 →
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635758116.008.00193002.26EPA 3809178 →
EVM5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21635446115.507.80177001.86EPA 3805578 →
EVM5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635446915.507.80177001.86EPA 3805586 →
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635477315.507.80179001.86EPA 3806338 →
EVM5X49M21A*+ furnace: *80VSL0901716B*AHRI reference: 21635472515.507.80180001.86EPA 3806507 →
EVM5X49M21A*+ furnace: *80VSL0902120B*AHRI reference: 21635473315.507.80179001.86EPA 3806515 →
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635482115.507.80179001.88EPA 3806697 →
EVM5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 21635462915.507.80178001.86EPA 3807589 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.