Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 21

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5496 / 496
EER2 · BTU/Wh11.7–14496 / 496
HSPF2 · BTU/Wh7.8–8.5496 / 496
Cooling capacity · BTU/h22,200–25,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000496 / 496
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500496 / 496
COP at 5°F / −15°C1.94–2.24496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X30M12A*+ furnace: OMV112K14AAHRI reference: 21636812816.008.00114002.02EPA 3809302 →
ESH5X30M12A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21636816016.008.00112002.06EPA 3809408 →
EA*5X36M17A*+ furnace: *96VSN0401410B*AHRI reference: 21636576016.007.80112001.98EPA 3809482 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21636729416.007.80113001.98EPA 3809577 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0801714B*AHRI reference: 21636730216.007.80112002.00EPA 3809588 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21636731016.007.80112002.00EPA 3809600 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21636731816.008.00112002.06EPA 3809611 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21636732616.007.80112002.00EPA 3809621 →
ESH5X30M12A*+ furnace: *96VTN0601412B*AHRI reference: 21636805616.007.80112002.00EPA 3809792 →
ESH5X30M12A*+ furnace: *96VTN0601716B*AHRI reference: 21636806416.007.80111002.00EPA 3809799 →
ESH5X30M12A*+ furnace: *96VTN0801716B*AHRI reference: 21636807216.007.80111002.02EPA 3809808 →
ESH5X24M12A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636690216.007.80112002.00EPA 3810032 →
ESH5X24M12A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 21636691016.007.80112002.00EPA 3810040 →
ESH5X24M12A*+ furnace: *80VSL0451412B*AHRI reference: 21636692616.007.80110002.02EPA 3810049 →
ESH5X24M12A*+ furnace: *80VTL0701716B*AHRI reference: 21636708616.007.80111002.00EPA 3810056 →
ESH5X24M12A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636705416.007.80112002.00EPA 3810076 →
ESH5X30M12A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21636800016.008.00112002.04EPA 3810183 →
ESH5X30M12A*+ furnace: *80VSL1352422B*AHRI reference: 21636762216.007.80110002.02EPA 3810287 →
ESH5X30M12A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 21636766216.008.00113002.06EPA 3810333 →
ESH5X30M12A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21636756616.007.80112002.00EPA 3810385 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →