Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 18

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5496 / 496
EER2 · BTU/Wh11.7–14496 / 496
HSPF2 · BTU/Wh7.8–8.5496 / 496
Cooling capacity · BTU/h22,200–25,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000496 / 496
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500496 / 496
COP at 5°F / −15°C1.94–2.24496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X30M12A*+ furnace: *96VSN1002120B*AHRI reference: 21636791316.507.80110002.02EPA 3811492 →
ESH5X30M12A*+ furnace: *96VSN1202422B*AHRI reference: 21636792516.507.80110002.02EPA 3811500 →
ESH5X30M12A*+ furnace: *95MSU0802120A*AHRI reference: 21636795916.508.00112002.06EPA 3811631 →
ESH5X30M12A*+ furnace: *95MSU1002120A*AHRI reference: 21636797116.508.00111002.08EPA 3811639 →
ESH5X36M12A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21636880816.507.80111002.02EPA 3811693 →
ESH5X36M12A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21636882416.508.00111002.06EPA 3811720 →
ESH5X36M12A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21636883216.508.00111002.08EPA 3811728 →
ESH5X30M12A*+ furnace: *95MSU1002122A*AHRI reference: 21636798216.507.80110002.04EPA 3811735 →
ESH5X30M12A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21636801616.508.00112002.06EPA 3811744 →
ESH5X30M12A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21636802416.508.00111002.08EPA 3811752 →
ESH5X30M12A*+WALLCON+ furnace: *97CTN1202422A*AHRI reference: 21636820016.508.00112002.06EPA 3811765 →
ESH5X36M12A*+ furnace: OMV112K14AAHRI reference: 21636877616.508.00113002.04EPA 3811793 →
EA*5X24M17A*+ furnace: *80VTL0451412B*AHRI reference: 21636466116.508.10110002.08EPA 3811892 →
EA*5X24M17A*+ furnace: *80VTL0701716B*AHRI reference: 21636466916.508.10110002.08EPA 3811900 →
EA*5X24M17A*+WALLCON+ furnace: *95CSU0601716B*AHRI reference: 21636467716.508.00110002.04EPA 3811911 →
EA*5X24M17A*+WALLCON+ furnace: *97CMN0601714B*AHRI reference: 21636468516.508.00111002.04EPA 3811919 →
EA*5X24M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636472516.508.10110002.06EPA 3811942 →
EA*5X24M17A*+ furnace: *96VSN0801716B*AHRI reference: 21636473316.508.10110002.06EPA 3811951 →
EA*5X24M17A*+ furnace: *95MSU0401712A*AHRI reference: 21636474116.507.80111001.96EPA 3811962 →
EA*5X24M14A*+ furnace: *80VSL0451412B*AHRI reference: 21636449316.508.10109002.08EPA 3811985 →