Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H6S36*K*AAA*

MAINLINE 16 SEER2 HP

30 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H6S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.530 / 30
EER2 · BTU/Wh11.7–1330 / 30
HSPF2 · BTU/Wh7.830 / 30
Cooling capacity · BTU/h33,800–36,80030 / 30
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,20030 / 30
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80030 / 30
Heating capacity at 5°F / −15°C · BTU/h16,700–18,10030 / 30
COP at 5°F / −15°C2–2.2430 / 30
Equipment / loop typeHP - Split System30 / 30
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)30 / 30
Compressor stagingSingle stage30 / 30
Connected capabilityNo30 / 30

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FHMA5*48L*C*AHRI reference: 21416532315.507.80175002.24EPA 3404280 →
FTMA5B48L0C*AHRI reference: 21416526715.507.80167002.18EPA 3404416 →
FEVB0048**+NAVA54801CKAHRI reference: 21427770415.507.80174002.22EPA 3415830 →
FMA5X36**AL*AHRI reference: 21442432915.507.80170002.00EPA 3425206 →
F5MA5*48L*C*AHRI reference: 21646404415.507.80175002.24EPA 3846956 →
FEVA0048**+NAVA54801CKAHRI reference: 21705167715.507.80174002.22EPA 4001138 →
EVD5X42M24A*+ furnace: *80MSU1002120A*AHRI reference: 21415565715.207.80181002.14EPA 3401967 →
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 21415432615.207.80170002.18EPA 3402087 →
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 21415433415.207.80176002.18EPA 3402095 →
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21415484115.207.80176002.18EPA 3402104 →
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21415484915.207.80173002.20EPA 3402112 →
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21415385415.207.80171002.16EPA 3402203 →
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21415476115.207.80175002.18EPA 3402347 →
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21415476915.207.80176002.20EPA 3402355 →
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21415479315.207.80175002.18EPA 3402363 →
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21415437415.207.80179002.20EPA 3402546 →
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21415438215.207.80180002.20EPA 3402556 →
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21415489715.207.80175002.18EPA 3402566 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21415492115.207.80175002.18EPA 3402573 →
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21415500915.207.80176002.18EPA 3402588 →