Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H3V36*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 5

564 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5564 / 564
EER2 · BTU/Wh10–13564 / 564
HSPF2 · BTU/Wh8.1–9.5564 / 564
Cooling capacity · BTU/h32,000–36,000564 / 564
Heating capacity at 47°F / 8.3°C · BTU/h33,400–39,500542 / 564
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800564 / 564
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600564 / 564
COP at 5°F / −15°C1.88–2.14564 / 564
Equipment / loop typeHP - Split System564 / 564
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)564 / 564
Compressor stagingContinuously variable564 / 564
Connected capabilityNo564 / 564

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+WALLCON+ furnace: *80CSU0401712A*Cold climate designationAHRI reference: 21593656222.008.50288002.02EPA 3733937 →
EVD5X60M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 21593657222.008.50286002.04EPA 3733947 →
EVM5X44M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21594032222.008.50286002.02EPA 3734049 →
EVM5X44M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593493222.008.50286002.02EPA 3734091 →
EVM5X44M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593495222.008.50286002.02EPA 3734111 →
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21594264822.008.50282002.04EPA 3734319 →
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21594265822.008.50282002.04EPA 3734387 →
EVD5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21594266822.008.50282002.04EPA 3734397 →
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21594049222.008.50284002.04EPA 3734407 →
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21594050222.008.50284002.04EPA 3734417 →
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21594260822.008.50282002.04EPA 3735728 →
EVM5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21594261822.008.50282002.04EPA 3735737 →
EVD5X61M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21594262822.008.50284002.04EPA 3735748 →
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21594263822.008.50284002.04EPA 3735757 →
EVD5X38M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21594058222.008.50284002.04EPA 3735800 →
EVD5X38M17A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21594059222.008.50286002.02EPA 3735810 →
EVD5X42M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21594071222.008.50284002.04EPA 3735876 →
EVD5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21594249822.008.50284002.02EPA 3735939 →
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21594250822.008.50282002.04EPA 3735949 →
EVD5X61M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21594252822.008.50282002.04EPA 3735969 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →