B5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 21
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X60M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218410886 | 19.50 | 9.00 | 26200 | 1.94 | EPA 4604608 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218410878 | 19.50 | 9.00 | 26000 | 1.96 | EPA 4604616 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218410870 | 19.50 | 9.00 | 26400 | 1.96 | EPA 4604624 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218410862 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604632 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218410846 | 19.50 | 9.00 | 26000 | 1.96 | EPA 4604648 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218410838 | 19.50 | 9.00 | 26000 | 1.96 | EPA 4604656 → |
ESH5X48M12A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218410830 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604664 → |
ESH5X48M12A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218410822 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604672 → |
ESH5X48M12A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218410814 | 19.50 | 9.00 | 26600 | 1.96 | EPA 4604680 → |
ESH5X48M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218410790 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604704 → |
ESH5X48M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218410782 | 19.50 | 9.00 | 26600 | 1.96 | EPA 4604712 → |
ESH5X48M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218410758 | 19.50 | 9.00 | 26600 | 1.94 | EPA 4604736 → |
ESH5X48M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218410750 | 19.50 | 9.00 | 26600 | 1.96 | EPA 4604744 → |
ESH5X48M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218410718 | 19.50 | 9.00 | 26400 | 1.96 | EPA 4604776 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218410694 | 19.50 | 9.00 | 26400 | 1.96 | EPA 4604800 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218410686 | 19.50 | 9.00 | 26400 | 1.96 | EPA 4604808 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218410678 | 19.50 | 9.00 | 26600 | 1.96 | EPA 4604816 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218410670 | 19.50 | 9.00 | 26600 | 1.96 | EPA 4604824 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218410638 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604856 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218410630 | 19.50 | 9.00 | 26400 | 1.94 | EPA 4604864 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →