B5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 16
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218412254 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607240 → |
EVD5X42M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218412246 | 20.50 | 8.10 | 28600 | 2.00 | EPA 4607248 → |
EVD5X42M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218412206 | 20.50 | 8.50 | 28400 | 2.06 | EPA 4607288 → |
EVD5X42M17A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412174 | 20.50 | 8.10 | 27400 | 2.00 | EPA 4607320 → |
EVD5X38M17A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218412142 | 20.50 | 8.50 | 29400 | 2.02 | EPA 4607344 → |
EVD5X37M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412046 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4607440 → |
EVD5X37M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218412038 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4607448 → |
EVD5X36M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218412022 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607464 → |
EVD5X36M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218412014 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607472 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218411990 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607496 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218411982 | 20.50 | 8.50 | 28400 | 2.06 | EPA 4607504 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218411974 | 20.50 | 8.10 | 27000 | 2.00 | EPA 4607512 → |
EVD5X36M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218411958 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607528 → |
EVD5X36M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218411950 | 20.50 | 8.10 | 28600 | 2.00 | EPA 4607536 → |
EVD5X36M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218411942 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607544 → |
EVD5X36M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218411918 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607568 → |
EVD5X36M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218411910 | 20.50 | 8.10 | 28600 | 2.00 | EPA 4607576 → |
EVD5X36M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218411870 | 20.50 | 8.50 | 28400 | 2.06 | EPA 4607616 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218409830 | 20.00 | 9.00 | 26000 | 1.96 | EPA 4601664 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218409806 | 20.00 | 9.00 | 26000 | 1.96 | EPA 4601688 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →