Heating performance & equipment details
Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 139 / 139 |
| EER2 · BTU/Wh | 8–9.5 | 139 / 139 |
| HSPF2 · BTU/Wh | 8.1–9 | 139 / 139 |
| Cooling capacity · BTU/h | 54,000–58,000 | 139 / 139 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 58,500–64,500 | 139 / 139 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 139 / 139 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 139 / 139 |
| COP at 5°F / −15°C | 1.86–2.1 | 139 / 139 |
| Equipment / loop type | HP - Split System | 139 / 139 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 139 / 139 |
| Compressor staging | Continuously variable | 139 / 139 |
| Connected capability | No | 139 / 139 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169590 | 18.00 | 9.00 | 44500 | 2.10 | EPA 4597242 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169585 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597246 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169578 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597259 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169577 | 18.00 | 9.00 | 44000 | 2.08 | EPA 4597260 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169576 | 18.00 | 9.00 | 44000 | 2.10 | EPA 4597261 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169575 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597262 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169573 | 18.00 | 9.00 | 45000 | 2.08 | EPA 4597264 → |
EVD5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169572 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597265 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169568 | 18.00 | 9.00 | 45000 | 2.08 | EPA 4597268 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169564 | 18.00 | 9.00 | 44500 | 2.10 | EPA 4597272 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169559 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597276 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169558 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597277 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169557 | 18.00 | 9.00 | 44000 | 2.10 | EPA 4597278 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169556 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597279 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169554 | 18.00 | 9.00 | 45000 | 2.06 | EPA 4597281 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169553 | 18.00 | 9.00 | 44500 | 2.08 | EPA 4597282 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169549 | 18.00 | 9.00 | 45000 | 2.06 | EPA 4597285 → |
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169537 | 18.00 | 8.50 | 41500 | 2.02 | EPA 4597293 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169529 | 18.00 | 8.50 | 41500 | 2.02 | EPA 4597300 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218169506 | 18.00 | 8.50 | 42000 | 2.02 | EPA 4597318 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.