B5H0V60*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 2
139 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 139 / 139 |
| EER2 · BTU/Wh | 8–9.5 | 139 / 139 |
| HSPF2 · BTU/Wh | 8.1–9 | 139 / 139 |
| Cooling capacity · BTU/h | 54,000–58,000 | 139 / 139 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 58,500–64,500 | 139 / 139 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 139 / 139 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 139 / 139 |
| COP at 5°F / −15°C | 1.86–2.1 | 139 / 139 |
| Equipment / loop type | HP - Split System | 139 / 139 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 139 / 139 |
| Compressor staging | Continuously variable | 139 / 139 |
| Connected capability | No | 139 / 139 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169562 | 18.50 | 9.00 | 45000 | 2.08 | EPA 4597273 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218169561 | 18.50 | 9.00 | 44500 | 2.10 | EPA 4597274 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169560 | 18.50 | 9.00 | 44500 | 2.08 | EPA 4597275 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169555 | 18.50 | 9.00 | 45000 | 2.08 | EPA 4597280 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218169540 | 18.50 | 9.00 | 41500 | 2.02 | EPA 4597290 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169539 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597291 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169538 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597292 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169535 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597294 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218169532 | 18.50 | 9.00 | 41500 | 2.02 | EPA 4597297 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169531 | 18.50 | 9.00 | 41500 | 1.90 | EPA 4597298 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169530 | 18.50 | 9.00 | 42000 | 1.90 | EPA 4597299 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169528 | 18.50 | 8.50 | 41000 | 2.04 | EPA 4597301 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169527 | 18.50 | 9.00 | 42000 | 1.90 | EPA 4597302 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218169513 | 18.50 | 9.00 | 41500 | 2.02 | EPA 4597311 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218169512 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597312 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218169511 | 18.50 | 9.00 | 42000 | 2.00 | EPA 4597313 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218169510 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597314 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218169509 | 18.50 | 9.00 | 42000 | 2.02 | EPA 4597315 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218169507 | 18.50 | 9.00 | 41500 | 2.02 | EPA 4597317 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218169502 | 18.50 | 9.00 | 42000 | 2.00 | EPA 4597322 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →