B5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 2
336 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 336 / 336 |
| EER2 · BTU/Wh | 9–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 336 / 336 |
| Cooling capacity · BTU/h | 43,500–49,000 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 336 / 336 |
| COP at 5°F / −15°C | 1.92–2.2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218169211 | 19.50 | 9.50 | 36600 | 2.10 | EPA 4597604 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218169210 | 19.50 | 9.50 | 36600 | 2.10 | EPA 4597605 → |
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 218169158 | 19.50 | 9.50 | 33000 | 2.20 | EPA 4597657 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169419 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4597402 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169418 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4597403 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169417 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4597404 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169416 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4597405 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169414 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4597407 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218169412 | 19.00 | 9.00 | 36800 | 2.12 | EPA 4597409 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169411 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4597410 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218169410 | 19.00 | 9.00 | 36800 | 2.10 | EPA 4597411 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218169409 | 19.00 | 9.00 | 36800 | 2.12 | EPA 4597412 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169408 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4597413 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218169407 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4597414 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169406 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4597415 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169405 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4597416 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218169403 | 19.00 | 9.00 | 36200 | 2.12 | EPA 4597418 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218169402 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4597419 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218169401 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4597420 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218169400 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4597421 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →