Kenmore / AIR-SOURCE HEAT PUMP

B5H0V48*K*AAA*

Deluxe 20 VS Heat Pump · source records, page 17

336 published source records · source checked Sep 21, 2026

SEER2 range15.5–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity43,500–49,000BTU/h

Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19.5336 / 336
EER2 · BTU/Wh9–10.5336 / 336
HSPF2 · BTU/Wh8.5–9.5336 / 336
Cooling capacity · BTU/h43,500–49,000336 / 336
Heating capacity at 47°F / 8.3°C · BTU/h47,000–50,000336 / 336
Heating capacity at 17°F / −8.3°C · BTU/h41,000–47,500336 / 336
Heating capacity at 5°F / −15°C · BTU/h33,000–37,600336 / 336
COP at 5°F / −15°C1.92–2.2336 / 336
Equipment / loop typeHP - Split System336 / 336
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)336 / 336
Compressor stagingContinuously variable336 / 336
Connected capabilityNo336 / 336

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X48M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21816912716.508.50342002.06EPA 4597680 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21816912616.508.50342002.06EPA 4597681 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21816912516.508.50342002.06EPA 4597682 →
ESH5X60M12A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21816933616.008.50342001.94EPA 4597485 →
ESH5X48M12A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21816932716.008.50348001.92EPA 4597491 →
ESH5X48M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21816932416.008.50344002.04EPA 4597492 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21816915116.008.50342001.94EPA 4597663 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816915016.008.50342001.96EPA 4597664 →
ESH5X60M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21816914716.008.50342001.94EPA 4597667 →
ESH5X60M12A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21816914116.008.50342001.94EPA 4597673 →
ESH5X48M12A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21816913216.008.50348001.92EPA 4597676 →
ESH5X48M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21816913116.008.50348001.92EPA 4597677 →
ESH5X48M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21816912816.008.50348001.92EPA 4597679 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21816912216.008.50346001.94EPA 4597683 →
ESH5X60M12A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21816913915.508.50346001.94EPA 4597674 →
ESH5X48M12A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21816912015.508.50352001.92EPA 4597684 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →