Deluxe 20 VS Heat Pump · source records, page 7
270 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 270 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 270 / 270 |
| EER2 · BTU/Wh | 9–11.5 | 270 / 270 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 270 / 270 |
| Cooling capacity · BTU/h | 32,600–35,400 | 270 / 270 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 270 / 270 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–31,400 | 270 / 270 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,400–26,000 | 270 / 270 |
| COP at 5°F / −15°C | 1.75–2.04 | 270 / 270 |
| Equipment / loop type | HP - Split System | 270 / 270 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 270 / 270 |
| Compressor staging | Continuously variable | 270 / 270 |
| Connected capability | No | 270 / 270 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218168409 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4580608 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218168406 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4580611 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218168405 | 17.50 | 9.00 | 25200 | 1.90 | EPA 4580612 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218168404 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4580613 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218168402 | 17.50 | 9.00 | 25000 | 1.88 | EPA 4580615 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218168401 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4580616 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218168395 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4580622 → |
EA*5X43M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218168389 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4580628 → |
EA*5X43M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218168387 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4580630 → |
EA*5X43M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218168386 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4580631 → |
EA*5X43M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218168380 | 17.50 | 9.00 | 25400 | 1.86 | EPA 4580637 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218168379 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4580638 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218168378 | 17.50 | 9.00 | 25800 | 1.84 | EPA 4580639 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218168376 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4580640 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218168375 | 17.50 | 9.00 | 25600 | 1.86 | EPA 4580641 → |
EA*5X42M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218168371 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4580642 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218168891 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4589158 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218168890 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589159 → |
EA*5X43M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218168884 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589165 → |
EA*5X43M21A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218168883 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589166 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.