R5H5S36*K*AAA*
15 SEER2 HP
29 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 29 / 29 |
| EER2 · BTU/Wh | 11.7–13 | 29 / 29 |
| HSPF2 · BTU/Wh | 7.8–8 | 29 / 29 |
| Cooling capacity · BTU/h | 33,800–36,800 | 29 / 29 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 29 / 29 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 29 / 29 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 29 / 29 |
| COP at 5°F / −15°C | 2–2.22 | 29 / 29 |
| Equipment / loop type | HP - Split System | 29 / 29 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 29 / 29 |
| Compressor staging | Single stage | 29 / 29 |
| Connected capability | No | 29 / 29 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051652 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001121 → |
FTMA5B48L0C*AHRI reference: 214179952 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404475 → |
FHMA5*48L*C*AHRI reference: 214180194 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404811 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277619 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415700 → |
FMA5X36**AL*AHRI reference: 214424304 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425191 → |
F5MA5*48L*C*AHRI reference: 216464013 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3846934 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214138244 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400374 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 214141847 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400407 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214139990 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400454 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 214142646 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400575 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 214141959 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400624 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 214142872 | 15.20 | 7.80 | 17500 | 2.20 | EPA 3400739 → |
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 214143062 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3400770 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 214140527 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400801 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214141354 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400822 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214141384 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400853 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 214142273 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400885 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 214141465 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400930 → |
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 214139769 | 15.20 | 7.80 | 17000 | 2.18 | EPA 3401027 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214138097 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3401057 → |