Keeprite / AIR-SOURCE HEAT PUMP

R5H5S36*K*AAA*

15 SEER2 HP

29 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for R5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1629 / 29
EER2 · BTU/Wh11.7–1329 / 29
HSPF2 · BTU/Wh7.8–829 / 29
Cooling capacity · BTU/h33,800–36,80029 / 29
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,40029 / 29
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80029 / 29
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10029 / 29
COP at 5°F / −15°C2–2.2229 / 29
Equipment / loop typeHP - Split System29 / 29
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)29 / 29
Compressor stagingSingle stage29 / 29
Connected capabilityNo29 / 29

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21705165216.008.00174002.18EPA 4001121 →
FTMA5B48L0C*AHRI reference: 21417995215.507.80167002.18EPA 3404475 →
FHMA5*48L*C*AHRI reference: 21418019415.507.80174002.18EPA 3404811 →
FEVB0048**+NAVA54801CKAHRI reference: 21427761915.507.80174002.22EPA 3415700 →
FMA5X36**AL*AHRI reference: 21442430415.507.80170002.00EPA 3425191 →
F5MA5*48L*C*AHRI reference: 21646401315.507.80174002.18EPA 3846934 →
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21413824415.207.80179002.20EPA 3400374 →
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21414184715.207.80175002.18EPA 3400407 →
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21413999015.207.80180002.20EPA 3400454 →
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21414264615.207.80176002.18EPA 3400575 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21414195915.207.80175002.18EPA 3400624 →
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21414287215.207.80175002.20EPA 3400739 →
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 21414306215.207.80181002.14EPA 3400770 →
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414052715.207.80179002.20EPA 3400801 →
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21414135415.207.80175002.18EPA 3400822 →
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21414138415.207.80176002.20EPA 3400853 →
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414227315.207.80176002.18EPA 3400885 →
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21414146515.207.80175002.18EPA 3400930 →
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413976915.207.80170002.18EPA 3401027 →
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413809715.207.80171002.16EPA 3401057 →