R5H5S31*K*AAA*
15 SEER2 HP
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,400–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*42L*C*AHRI reference: 217683379 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506001 → |
F5MA5*42L*C*AHRI reference: 217683380 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4506002 → |
FMA5X30**AL*AHRI reference: 217683612 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506064 → |
FM(C,U)5Z36**AL*AHRI reference: 217683516 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506127 → |
FM(C,U)5Z30**AL*AHRI reference: 217683484 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506701 → |
FMA5X36**AL*AHRI reference: 217683644 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506749 → |
FHMA5*30L*B*AHRI reference: 217683251 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505710 → |
F5MA5*30L*B*AHRI reference: 217683252 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505711 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 217691569 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506787 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 217693095 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506813 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 217690837 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506830 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 217690860 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506852 → |
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 217690009 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506866 → |
EA*5X37M21A*+ furnace: *80CSU0401712B*AHRI reference: 217689965 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506888 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 217690882 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506906 → |
EA*5X43M21A*+ furnace: *80CSU0401712B*AHRI reference: 217691812 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506944 → |
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 217693513 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506958 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217690175 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506981 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217690200 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507006 → |
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 217691856 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4507034 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →