Keeprite / AIR-SOURCE HEAT PUMP

R5H5S18*K*AAA*

15 SEER2 HP

47 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,400–18,900BTU/h

Each efficiency range summarizes published EPA records for R5H5S18*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 47 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.547 / 47
EER2 · BTU/Wh11.7–12.547 / 47
HSPF2 · BTU/Wh7.8–847 / 47
Cooling capacity · BTU/h17,400–18,90047 / 47
Heating capacity at 47°F / 8.3°C · BTU/h16,400–18,30047 / 47
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,00047 / 47
Heating capacity at 5°F / −15°C · BTU/h8,200–8,60047 / 47
COP at 5°F / −15°C1.88–2.147 / 47
Equipment / loop typeHP - Split System47 / 47
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)47 / 47
Compressor stagingSingle stage47 / 47
Connected capabilityNo47 / 47

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X32M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21419548315.507.8082001.94EPA 3405057
EVM5X32M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21419545315.507.8082001.94EPA 3406138
FMA5X24**AL*AHRI reference: 21442393615.508.0082002.10EPA 3425259
EA*5X19M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21412478815.207.8084002.02EPA 3398542
EA*5X19M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21412481815.207.8084002.04EPA 3398572
EA*5X25M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21412610115.207.8084002.04EPA 3398631
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21412669015.207.8084002.04EPA 3398655
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*AHRI reference: 21412616115.207.8084002.06EPA 3398718
EA*5X25M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21412619315.207.8084002.06EPA 3398750
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21412673215.207.8085002.04EPA 3398785
EA*5X25M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21412622315.207.8085002.06EPA 3398802
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21412625515.207.8084002.04EPA 3398834
EA*5X19M17A*+ furnace: *80MS(N,L)0701712A*AHRI reference: 21412484815.207.8083002.04EPA 3398848
EA*5X19M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21412487615.207.8084002.04EPA 3398876
EA*5X19M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21412490615.207.8084002.04EPA 3398912
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 21412703115.207.8084002.06EPA 3398958
EA*5X19M17A*+ furnace: *92MSN0801716A*AHRI reference: 21412557715.207.8084002.04EPA 3398967
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21412636115.207.8084002.04EPA 3398980
EA*5X25M17A*+ furnace: *80ESU0401712A*AHRI reference: 21412641415.207.8084002.06EPA 3399008
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21412647815.207.8084002.06EPA 3399061

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →