Keeprite / AIR-SOURCE HEAT PUMP

Q5H9V60*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 5

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21793221116.008.50410002.00EPA 4545082 →
EA*5X60M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793162516.009.00405002.12EPA 4545266 →
EA*5X60M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793155016.008.50405002.00EPA 4545270 →
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21793156516.008.50400002.00EPA 4545307 →
EA*5X60M24A*+ furnace: *80CTL0902120B*AHRI reference: 21793158016.009.00405002.12EPA 4545322 →
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21793216616.009.00405002.14EPA 4545332 →
F5MA5*60L*D*AHRI reference: 21793336816.009.00400002.16EPA 4545361 →
EA*5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793261616.009.00410002.14EPA 4545513 →
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21793263116.009.00405002.14EPA 4545528 →
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 21793264716.008.50405002.05EPA 4545544 →
EA*5X61M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21793285716.009.00410002.14EPA 4545669 →
EA*5X61M24A*+ furnace: *97CTN1202422A*AHRI reference: 21793287216.009.00405002.14EPA 4545693 →
EA*5X60M24A*+ furnace: *80CTL1352422B*AHRI reference: 21793161016.009.00405002.12EPA 4545706 →
EA*5X60M24A*+ furnace: *80CTL1102120B*AHRI reference: 21793159516.009.00405002.12EPA 4545773 →
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21793164016.009.00405002.12EPA 4545777 →
EA*5X61M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793290216.009.00410002.14EPA 4545849 →
EA*5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21793291716.009.00405002.14EPA 4545866 →
EA*5X61M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 21793293216.009.00410002.14EPA 4545881 →
EA*5X61M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21793224116.008.50410002.05EPA 4545987 →
EA*5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21793231616.008.50410002.00EPA 4546004 →