Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 5
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217917903 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4540975 → |
EVD5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217917916 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4540988 → |
EVD5X61M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217917929 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4541000 → |
EVD5X61M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217918060 | 16.50 | 9.00 | 40500 | 2.15 | EPA 4541019 → |
EVD5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217917655 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4541329 → |
EVD5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217917681 | 16.50 | 9.00 | 41000 | 2.10 | EPA 4541353 → |
EVD5X61M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217917707 | 16.50 | 9.00 | 41000 | 2.10 | EPA 4541379 → |
EVD5X61M24A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217917799 | 16.50 | 9.00 | 40000 | 2.15 | EPA 4541661 → |
EVD5X61M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217917786 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4541676 → |
EVD5X61M24A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217918178 | 16.50 | 9.50 | 40500 | 2.24 | EPA 4541730 → |
EA*5X61M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217929442 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4542064 → |
EA*5X61M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217929455 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4542077 → |
EA*5X61M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217929559 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4542326 → |
EA*5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217928570 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4542393 → |
EA*5X60M24A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217929038 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4542430 → |
EA*5X60M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217929064 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4542455 → |
ESH5X60M12A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217930809 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4542638 → |
EA*5X61M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217929572 | 16.50 | 9.00 | 37400 | 2.10 | EPA 4542699 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217929975 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4542980 → |
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217929728 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4543291 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →