Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 22
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X60M12A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 217931239 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4546316 → |
ESH5X48M12A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217930666 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4546545 → |
ESH5X48M12A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217930705 | 15.50 | 8.50 | 36600 | 2.00 | EPA 4546581 → |
ESH5X60M12A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217931265 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4546595 → |
EA*5X61M24A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217929897 | 15.50 | 9.00 | 37200 | 2.10 | EPA 4546706 → |
ESH5X60M12A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217931174 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4547171 → |
EA*5X61M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217930210 | 15.50 | 9.00 | 37200 | 2.12 | EPA 4547253 → |
EA*5X61M24A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217930223 | 15.50 | 9.00 | 37400 | 2.10 | EPA 4547263 → |
ESH5X60M12A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217931213 | 15.50 | 9.00 | 36800 | 2.10 | EPA 4547451 → |
EA*5X60M24A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217929377 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4547466 → |
ESH5X48M12A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217953209 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4557024 → |
ESH5X48M12A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 217953237 | 15.50 | 8.50 | 36800 | 2.00 | EPA 4557052 → |
EA*5X60M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217952746 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4557165 → |
EA*5X48M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217952660 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4557288 → |
EA*5X48M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217952646 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4557411 → |
EVD5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217953321 | 15.50 | 9.00 | 40500 | 2.10 | EPA 4557581 → |
EA*5X61M21A*+TDRCold climate designationAHRI reference: 217954433 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4558643 → |
EA*5X61M24A*+TDRCold climate designationAHRI reference: 217954447 | 15.50 | 9.00 | 36800 | 2.08 | EPA 4558657 → |
EA*5X61M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217952914 | 15.50 | 9.00 | 37400 | 2.10 | EPA 4560291 → |
EA*5X61M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217952928 | 15.50 | 9.00 | 37600 | 2.10 | EPA 4560305 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.