Keeprite / AIR-SOURCE HEAT PUMP

Q5H9V48*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 19

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X49M24A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21791687815.509.00410002.12EPA 4536365 →
EVD5X60M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21791712615.509.00405002.12EPA 4536382 →
EVD5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21791631715.509.00400002.10EPA 4536445 →
EVD5X48M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21791634315.509.00400002.10EPA 4536460 →
EVD5X49M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21791686515.509.00405002.12EPA 4536731 →
EVD5X49M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791689215.509.00410002.12EPA 4536884 →
EVD5X49M24A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21791691815.509.00410002.12EPA 4536906 →
EVD5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21791642115.509.00400002.10EPA 4537041 →
EVD5X61M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21791794315.509.00410002.12EPA 4537199 →
EVD5X49M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21791693115.509.00410002.12EPA 4537451 →
EVD5X60M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21791695715.509.00400002.10EPA 4537485 →
EVD5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21791646015.509.00400002.10EPA 4537564 →
EVD5X48M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21791639515.509.50400002.24EPA 4537866 →
EVD5X61M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21791762915.509.00405002.12EPA 4537902 →
EVD5X61M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 21791824415.509.00405002.12EPA 4538059 →
EVD5X60M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791732215.509.50405002.24EPA 4538486 →
EVD5X48M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21791649915.509.00395002.10EPA 4538515 →
EVD5X60M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21791736915.509.50405002.24EPA 4538527 →
EVD5X48M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21791648615.509.00400002.10EPA 4538552 →
EVD5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791657815.509.50400002.22EPA 4538932 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →