Keeprite / AIR-SOURCE HEAT PUMP

Q5H9V36*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 10

450 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18450 / 450
EER2 · BTU/Wh10.5–13.5450 / 450
HSPF2 · BTU/Wh7.8–9450 / 450
Cooling capacity · BTU/h33,400–37,600450 / 450
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400450 / 450
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600450 / 450
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600450 / 450
COP at 5°F / −15°C1.9–2.18450 / 450
Equipment / loop typeHP - Split System450 / 450
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)450 / 450
Compressor stagingContinuously variable450 / 450
Connected capabilityNo450 / 450

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 21792278715.509.00256002.08EPA 4537681
EA*5X36M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21792213815.508.50252002.00EPA 4537711
EA*5X43M21A*+ furnace: *97CTN1002122A*AHRI reference: 21792523515.509.00248002.06EPA 4537774
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21792470915.509.00246002.04EPA 4537908
EA*5X43M21A*+ furnace: *80CTL0702120B*AHRI reference: 21792478415.509.00248002.06EPA 4537951
EA*5X37M21A*+ furnace: *96VTN1002120B*AHRI reference: 21792373315.509.00248002.08EPA 4538173
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21792374815.508.50246001.96EPA 4538187
EA*5X43M21A*+ furnace: *97CTN0802120A*AHRI reference: 21792522015.509.00248002.08EPA 4538209
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 21792269515.509.00256002.08EPA 4538221
EA*5X37M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21792271115.509.00256002.08EPA 4538236
EA*5X43M21A*+ furnace: *97VTN0802120A*AHRI reference: 21792535515.509.00248002.08EPA 4538254
EA*5X43M21A*+ furnace: *97VTN1002120A*AHRI reference: 21792537015.509.00248002.08EPA 4538271
EA*5X43M21A*+ furnace: *80CTL0901716B*AHRI reference: 21792479915.509.00248002.08EPA 4538357
EA*5X43M21A*+ furnace: *80CTL0902120B*AHRI reference: 21792481415.509.00248002.06EPA 4538360
EA*5X43M21A*+ furnace: *80CTL1102120B*AHRI reference: 21792482915.509.00246002.06EPA 4538384
EA*5X43M21A*+ furnace: *80VTL0701716B*AHRI reference: 21792484415.509.00248002.06EPA 4538400
EA*5X37M21A*+ furnace: *97CTN0802120A*AHRI reference: 21792365815.509.00248002.08EPA 4538436
EA*5X37M21A*+ furnace: *97CTN1002122A*AHRI reference: 21792367315.509.00248002.06EPA 4538632
EA*5X37M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 21792295215.509.00256002.08EPA 4538887
EA*5X37M21A*+ furnace: *96VTN0802120B*AHRI reference: 21792371815.509.00248002.08EPA 4538908

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →