Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 25
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217945612 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4563210 → |
EA*5X37M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217948261 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4563457 → |
EA*5X37M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217948276 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4563826 → |
EA*5X37M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217948291 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4563841 → |
EA*5X37M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217949169 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4564042 → |
EA*5X37M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217949154 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4564240 → |
EA*5X37M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217945627 | 18.50 | 10.00 | 21200 | 1.96 | EPA 4564621 → |
EVM5X24M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217935305 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4542576 → |
EVM5X24M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217935320 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4542589 → |
EVM5X24M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217935260 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4544695 → |
EVM5X24M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217935275 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4544711 → |
EVM5X24M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217935290 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4544726 → |
EVM5X24M14A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217935153 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4546497 → |
EVM5X24M14A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217935108 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4547216 → |
EVM5X24M14A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217935123 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4547237 → |
FTMA5X24L0B*Cold climate designationAHRI reference: 217935093 | 18.00 | 9.50 | 21400 | 1.92 | EPA 4547296 → |
EVM5X24M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217935729 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4547792 → |
EVD5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217939377 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4547840 → |
EVD5X36M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217941709 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4547903 → |
EVD5X24M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217939104 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4547948 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.