Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 12
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X25M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217936212 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553668 → |
EVM5X25M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217936227 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553683 → |
EVM5X36M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217938725 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553693 → |
EVM5X25M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217936047 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553757 → |
EVM5X31M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217937197 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553775 → |
EVM5X31M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217937212 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4553790 → |
EVM5X31M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217937347 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4553810 → |
EVD5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217941452 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553839 → |
EVM5X25M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217936031 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553894 → |
EVD5X36M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217942410 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553968 → |
EVD5X36M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217942425 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4553983 → |
EVM5X32M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217937710 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554059 → |
EVM5X32M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217937725 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554074 → |
EVM5X32M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217937740 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554088 → |
EVM5X32M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217937847 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554100 → |
EVM5X32M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217937862 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554116 → |
EVD5X36M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217941892 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4554124 → |
EVD5X36M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217941907 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4554139 → |
EVD5X36M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217941937 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554155 → |
EVD5X36M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217941952 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554171 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →