Keeprite / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 9

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21791887015.508.00395001.96EPA 4541236
ESH5X60M12A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793303015.508.50405002.04EPA 4542414
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793226415.508.50410002.00EPA 4542786
EA*5X60M24A*+ furnace: *97VTN1202422A*AHRI reference: 21793197915.509.00405002.14EPA 4543265
EA*5X60M24A*+ furnace: *97CTN1002122A*AHRI reference: 21793184415.509.00405002.12EPA 4543457
EA*5X61M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21793209915.508.50410002.00EPA 4543518
EA*5X61M24A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21793270015.508.50410002.05EPA 4543715
EA*5X60M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793188915.509.00405002.12EPA 4543973
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21793191915.509.00405002.14EPA 4544000
EA*5X61M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793276015.508.50410002.00EPA 4544190
EA*5X61M24A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21793274515.508.50410002.00EPA 4544207
EA*5X61M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21793279015.508.50410002.05EPA 4544418
EA*5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21793283515.508.50410002.05EPA 4544462
EA*5X60M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793194915.509.00405002.12EPA 4544592
EA*5X61M21A*+ furnace: *80CSU0401712B*AHRI reference: 21793200915.508.50405002.00EPA 4544633
ESH5X60M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793307515.508.50405002.04EPA 4544945
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21793179915.509.00405002.12EPA 4545009
EA*5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21793217415.508.50405002.00EPA 4545045
EA*5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21793218915.508.50410002.00EPA 4545061
EA*5X61M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21793221915.508.50410002.00EPA 4545343

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →