N5H9V60*K*AAA*
Performance 19 SEER2 VS HP · source records, page 3
212 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 212 / 212 |
| EER2 · BTU/Wh | 10–12 | 212 / 212 |
| HSPF2 · BTU/Wh | 8–9 | 212 / 212 |
| Cooling capacity · BTU/h | 54,000–57,500 | 212 / 212 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–62,000 | 212 / 212 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–50,500 | 212 / 212 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–42,000 | 212 / 212 |
| COP at 5°F / −15°C | 1.94–2.16 | 212 / 212 |
| Equipment / loop type | HP - Split System | 212 / 212 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 212 / 212 |
| Compressor staging | Continuously variable | 212 / 212 |
| Connected capability | No | 212 / 212 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 217921009 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4541068 → |
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 217921024 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4541085 → |
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 217921039 | 16.00 | 8.00 | 40000 | 1.96 | EPA 4541099 → |
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 217920136 | 16.00 | 8.00 | 39500 | 1.96 | EPA 4541121 → |
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 217918495 | 16.00 | 8.00 | 39000 | 1.94 | EPA 4541146 → |
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 217918510 | 16.00 | 8.00 | 39000 | 1.94 | EPA 4541151 → |
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 217918525 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4541174 → |
EVM5X60M21A*+ furnace: *97CTN1002122A*AHRI reference: 217918855 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4541221 → |
EVM5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 217918886 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4541252 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 217932504 | 16.00 | 9.00 | 40500 | 2.12 | EPA 4541964 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217932534 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4541993 → |
EA*5X61M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217932549 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4542009 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217932279 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4542800 → |
EA*5X61M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217932024 | 16.00 | 8.50 | 41000 | 2.05 | EPA 4543232 → |
EA*5X61M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217932039 | 16.00 | 9.00 | 41000 | 2.14 | EPA 4543246 → |
EA*5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217932069 | 16.00 | 8.50 | 41000 | 2.00 | EPA 4543412 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 217932084 | 16.00 | 8.50 | 40500 | 2.00 | EPA 4543427 → |
EA*5X60M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217931859 | 16.00 | 9.00 | 40500 | 2.12 | EPA 4543473 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217932054 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4543508 → |
EA*5X60M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217931513 | 16.00 | 9.00 | 40500 | 2.12 | EPA 4543555 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →