Performance 19 SEER2 VS HP · source records, page 6
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217929970 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4542976 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217929983 | 16.50 | 9.00 | 37400 | 2.08 | EPA 4542988 → |
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217929723 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4543286 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217928643 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543588 → |
EA*5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217928669 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543613 → |
EA*5X60M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217929150 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4543652 → |
EA*5X60M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217929163 | 16.50 | 9.00 | 37200 | 2.10 | EPA 4543665 → |
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217929176 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4543676 → |
EA*5X60M24A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217929190 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4543809 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217928747 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4543893 → |
EA*5X61M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217929814 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4544069 → |
EA*5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217928708 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544105 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217928721 | 16.50 | 9.00 | 36800 | 2.08 | EPA 4544119 → |
EA*5X48M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217928760 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4544289 → |
EA*5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217928773 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544302 → |
EA*5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217928786 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4544315 → |
EA*5X48M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217928799 | 16.50 | 9.00 | 37000 | 2.08 | EPA 4544328 → |
EA*5X61M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217929853 | 16.50 | 9.00 | 37000 | 2.10 | EPA 4544568 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217928617 | 16.50 | 9.00 | 36800 | 2.10 | EPA 4544661 → |
EA*5X48M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217928630 | 16.50 | 9.00 | 36600 | 2.10 | EPA 4544673 → |