N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 2
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217928656 | 17.00 | 9.00 | 36600 | 2.10 | EPA 4543599 → |
EA*5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217929762 | 17.00 | 9.00 | 37200 | 2.10 | EPA 4544009 → |
EA*5X61M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217929788 | 17.00 | 9.00 | 37200 | 2.10 | EPA 4544038 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217929098 | 17.00 | 9.00 | 36800 | 2.10 | EPA 4544519 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217929827 | 17.00 | 9.50 | 36600 | 2.22 | EPA 4544542 → |
EA*5X61M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217929866 | 17.00 | 9.50 | 36600 | 2.22 | EPA 4544581 → |
EA*5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217928591 | 17.00 | 9.00 | 36800 | 2.08 | EPA 4544868 → |
EA*5X61M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217929502 | 17.00 | 9.00 | 37000 | 2.10 | EPA 4544976 → |
EA*5X48M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217929007 | 17.00 | 9.00 | 36800 | 2.12 | EPA 4546385 → |
EA*5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217929671 | 17.00 | 9.00 | 37200 | 2.10 | EPA 4546905 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217928955 | 17.00 | 9.00 | 36800 | 2.12 | EPA 4547069 → |
EVM5X60M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217915908 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4530048 → |
EVM5X49M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217915739 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4530063 → |
EVM5X49M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217915778 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4530729 → |
EVM5X60M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217915882 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4530737 → |
EVD5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217916247 | 16.50 | 9.00 | 39500 | 2.10 | EPA 4530947 → |
EVD5X48M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217916299 | 16.50 | 9.00 | 39500 | 2.10 | EPA 4531079 → |
EVD5X49M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217916690 | 16.50 | 9.00 | 40000 | 2.10 | EPA 4531475 → |
EVM5X60M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217915843 | 16.50 | 9.50 | 40000 | 2.24 | EPA 4531903 → |
EVM5X60M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217915856 | 16.50 | 9.00 | 40500 | 2.10 | EPA 4531915 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →