N5H8T60*K*AAA*
2-STAGE 18 SEER HP
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 122 / 122 |
| EER2 · BTU/Wh | 11.7–13 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 122 / 122 |
| Cooling capacity · BTU/h | 54,000–58,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 122 / 122 |
| COP at 5°F / −15°C | 2.1–2.34 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560750 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982835 → |
QFVA5D6021X*AHRI reference: 218695468 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683359 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215629098 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951011 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215629897 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951143 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215629975 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951214 → |
EA*5X61M24A*+ furnace: *80CSU0802120A*AHRI reference: 215629988 | 16.50 | 7.80 | 31400 | 2.22 | EPA 3951265 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215630029 | 16.50 | 8.10 | 29800 | 2.14 | EPA 3951390 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215630042 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951405 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 215630058 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951421 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 215630077 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951437 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215629584 | 16.50 | 8.10 | 30000 | 2.12 | EPA 3951539 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215629619 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951577 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 215630107 | 16.50 | 8.10 | 30200 | 2.26 | EPA 3951610 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 215630121 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951627 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215630135 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951642 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 215630168 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951674 → |
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 215630205 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951712 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215629696 | 16.50 | 8.00 | 30400 | 2.25 | EPA 3951768 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215629729 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951800 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 215630247 | 16.50 | 8.10 | 30400 | 2.12 | EPA 3951813 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →