Keeprite / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 20

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21563307115.508.10262002.18EPA 3953631 →
ESH5X48M12A*+ furnace: *95MSU1002122A*AHRI reference: 21563381315.507.80248002.20EPA 3953715 →
ESH5X48M12A*+ furnace: *96CTN0802120B*AHRI reference: 21563382715.507.80250002.08EPA 3953726 →
ESH5X48M12A*+ furnace: *80CSU0802120A*AHRI reference: 21563330015.507.80252002.08EPA 3953757 →
ESH5X60M12A*+ furnace: *80CSU0802120A*AHRI reference: 21563401815.507.80252002.10EPA 3953890 →
EA*5X61M24A*+ furnace: *97CTN1202422A*AHRI reference: 21572185415.508.00260002.20EPA 3982276 →
EA*5X60M24A*+ furnace: *97CMN1202422B*AHRI reference: 21563206815.208.10258002.20EPA 3952656 →
EA*5X60M24A*+ furnace: *95MSU0802120A*AHRI reference: 21563212415.208.10258002.20EPA 3952713 →
ESH5X48M12A*+ furnace: *80MSU0601716A*AHRI reference: 21563338315.207.80250002.15EPA 3953798 →
ESH5X48M12A*+ furnace: *80MSU0802120A*AHRI reference: 21563340215.207.80248002.20EPA 3953819 →
ESH5X60M12A*+ furnace: *95MSU1002122A*AHRI reference: 21563453115.207.80250002.20EPA 3953931 →
ESH5X60M12A*+ furnace: *95MSU0802120A*AHRI reference: 21563449615.207.80252002.20EPA 3954029 →
ESH5X60M12A*+ furnace: *80MSU1002120A*AHRI reference: 21563413915.207.80250002.20EPA 3954130 →
ESH5X60M12A*+ furnace: *95CSU1002122B*AHRI reference: 21563432515.207.80250002.20EPA 3954242 →
ESH5X60M12A*+ furnace: OLV154F20AAHRI reference: 21563470815.207.80250002.20EPA 3954381 →
ESH5X60M12A*+ furnace: *95MSU1002120A*AHRI reference: 21563451515.207.80254002.20EPA 4000903 →
ESH5X60M12A*+ furnace: *95CSU0802120B*AHRI reference: 21563431115.207.80252002.15EPA 4000944 →
ESH5X48M12A*+ furnace: *80CTL0902120B*AHRI reference: 21563347915.208.00248002.20EPA 4000955 →
ESH5X48M12A*+ furnace: *96VSN1202422B*AHRI reference: 21563374315.208.00248002.20EPA 4000981 →
ESH5X48M12A*+ furnace: *80MSU1002120A*AHRI reference: 21563342115.207.80250002.15EPA 4000991 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →