Keeprite / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 18

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572179316.008.00254002.25EPA 3981841 →
EA*5X61M21A*+ furnace: *97VTN0802120A*AHRI reference: 21572181016.008.00256002.20EPA 3981861 →
EA*5X61M21A*+ furnace: *97VTN1002120A*AHRI reference: 21572182616.008.00256002.20EPA 3981876 →
EA*5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572173916.008.00248002.24EPA 3982219 →
EA*5X60M24A*+ furnace: *80CSU0802120B*AHRI reference: 21572175216.008.00254002.20EPA 3982228 →
EA*5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21572186816.008.00258002.20EPA 3982284 →
EVM5X60M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572202516.008.00246002.12EPA 3982440 →
ESH5X60M12A*+ furnace: *97VTN1002122A*AHRI reference: 21571800216.008.00250002.25EPA 4000884 →
ESH5X60M12A*+ furnace: *97CMN1002122B*AHRI reference: 21563438116.008.00252002.25EPA 4000916 →
ESH5X60M12A*+ furnace: *97CMN0802120B*AHRI reference: 21563436716.008.00252002.20EPA 4000930 →
ESH5X60M12A*+ furnace: *80CSU0802120B*AHRI reference: 21571784816.007.80250002.20EPA 4001051 →
EA*5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563121315.508.10252002.22EPA 3951995 →
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21563125415.508.10250002.20EPA 3952010 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563136515.508.10254002.20EPA 3952209 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563142615.508.10250002.20EPA 3952327 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563147115.508.10254002.20EPA 3952358 →
EA*5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 21563152715.508.10252002.22EPA 3952383 →
EA*5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21563154115.508.10252002.20EPA 3952401 →
EA*5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21563158115.508.10252002.22EPA 3952412 →
EA*5X48M21A*+ furnace: *95MSU0802120A*AHRI reference: 21563162915.508.10252002.20EPA 3952428 →