N5H8T36*K*AAA*
2-STAGE 18 SEER HP · source records, page 6
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 257 / 257 |
| EER2 · BTU/Wh | 11.7–13 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 257 / 257 |
| Cooling capacity · BTU/h | 33,800–38,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 257 / 257 |
| COP at 5°F / −15°C | 1.78–2.48 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 257 / 257 |
| Compressor staging | Two-stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *80VSL0901716B*AHRI reference: 215637686 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955473 → |
EA*5X43M21A*+ furnace: *80VSL0902120B*AHRI reference: 215637706 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955488 → |
EA*5X43M21A*+ furnace: *80MSU0401712A*AHRI reference: 215637749 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955516 → |
EA*5X43M21A*+ furnace: *96VTN0802120B*AHRI reference: 215638580 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955567 → |
EA*5X43M21A*+ furnace: *80MSU1002120A*AHRI reference: 215637833 | 15.50 | 8.10 | 19400 | 2.24 | EPA 3955585 → |
EA*5X43M21A*+ furnace: *96CTN1002122B*AHRI reference: 215638498 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955636 → |
EA*5X43M21A*+ furnace: *96VSN0802120B*AHRI reference: 215638282 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955674 → |
EA*5X43M21A*+ furnace: *96VSN1002120B*AHRI reference: 215638302 | 15.50 | 8.10 | 19400 | 2.26 | EPA 3955697 → |
EA*5X43M21A*+ furnace: *80CTL0702120B*AHRI reference: 215637903 | 15.50 | 8.10 | 19400 | 2.24 | EPA 3955729 → |
EA*5X43M21A*+ furnace: *80CTL0901716B*AHRI reference: 215637922 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955747 → |
EA*5X43M21A*+ furnace: *80CTL0902120B*AHRI reference: 215637943 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955757 → |
EA*5X43M21A*+ furnace: *80CTL1102120B*AHRI reference: 215637963 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955774 → |
EA*5X43M21A*+ furnace: *80VTL0701716B*AHRI reference: 215637989 | 15.50 | 8.10 | 19400 | 2.24 | EPA 3955789 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 215638797 | 15.50 | 8.10 | 19200 | 2.26 | EPA 3955812 → |
EA*5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 215638816 | 15.50 | 8.10 | 19100 | 2.24 | EPA 3955826 → |
EA*5X48M21A*+ furnace: *80MSU0401712A*AHRI reference: 215638840 | 15.50 | 8.10 | 19200 | 2.24 | EPA 3955842 → |
EA*5X43M21A*+ furnace: *80VTL0902120B*AHRI reference: 215638027 | 15.50 | 8.10 | 19300 | 2.24 | EPA 3955882 → |
EA*5X43M21A*+ furnace: *80VTL1102122B*AHRI reference: 215638052 | 15.50 | 8.10 | 19200 | 2.40 | EPA 3955900 → |
EA*5X43M21A*+ furnace: *95CSU0802120B*AHRI reference: 215638096 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955927 → |
EA*5X43M21A*+ furnace: *95CSU1002122B*AHRI reference: 215638116 | 15.50 | 8.10 | 19300 | 2.26 | EPA 3955940 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.