N5H8T36*K*AAA*
2-STAGE 18 SEER HP · source records, page 13
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 257 / 257 |
| EER2 · BTU/Wh | 11.7–13 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 257 / 257 |
| Cooling capacity · BTU/h | 33,800–38,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 257 / 257 |
| COP at 5°F / −15°C | 1.78–2.48 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 257 / 257 |
| Compressor staging | Two-stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+ furnace: *96CTN1002122B*AHRI reference: 215642821 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956774 → |
ESH5X48M12A*+ furnace: *96VTN1002120B*AHRI reference: 215642925 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956796 → |
ESH5X48M12A*+ furnace: *96VTN1002122B*AHRI reference: 215642948 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956808 → |
ESH5X48M12A*+ furnace: *96VTN1202422B*AHRI reference: 215642974 | 15.20 | 8.10 | 19300 | 2.24 | EPA 3956837 → |
ESH5X48M12A*+ furnace: OLV154F20AAHRI reference: 215642992 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956844 → |
ESH5X42M12A*+ furnace: *80VTL1102122B*AHRI reference: 215641340 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3956854 → |
ESH5X42M12A*+ furnace: *95CSU1002122B*AHRI reference: 215641428 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3956872 → |
ESH5X42M12A*+ furnace: *96VTN1002122B*AHRI reference: 215641901 | 15.20 | 7.80 | 18800 | 2.26 | EPA 3956890 → |
ESH5X42M12A*+ furnace: OLV154F20AAHRI reference: 215641947 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3956903 → |
ESH5X48M12A*+ furnace: *80VSL0902120B*AHRI reference: 215642086 | 15.20 | 8.10 | 19200 | 2.24 | EPA 3957101 → |
ESH5X48M12A*+ furnace: *80VSL1102122B*AHRI reference: 215642106 | 15.20 | 8.10 | 19100 | 2.26 | EPA 3957116 → |
ESH5X48M12A*+ furnace: *80MSU0601716A*AHRI reference: 215642179 | 15.20 | 8.10 | 19000 | 2.26 | EPA 3957129 → |
ESH5X48M12A*+ furnace: *80MSU0802120A*AHRI reference: 215642206 | 15.20 | 8.10 | 19000 | 2.26 | EPA 3957151 → |
ESH5X48M12A*+ furnace: *80MSU1002120A*AHRI reference: 215642234 | 15.20 | 7.80 | 19000 | 2.26 | EPA 3957163 → |
ESH5X48M12A*+ furnace: *80CTL0902120B*AHRI reference: 215642347 | 15.20 | 8.10 | 19000 | 2.26 | EPA 3957184 → |
FTMA5B36L0C*AHRI reference: 215560698 | 15.20 | 8.10 | 18800 | 2.20 | EPA 3982794 → |
EA*5X37M17A*+ furnace: *97VTN0601716A*AHRI reference: 215721333 | 15.20 | 8.10 | 19000 | 2.24 | EPA 4705719 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →