Keeprite / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21564858817.508.00112002.10EPA 3719651 →
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21561383317.507.80109001.98EPA 3945997 →
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564439417.508.10110002.10EPA 3957781 →
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564445317.508.10111002.10EPA 3957825 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21564450517.508.10110002.10EPA 3957857 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564457017.508.10111002.10EPA 3957899 →
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564459017.508.10111002.10EPA 3957917 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564461517.508.10110002.10EPA 3957930 →
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564465917.508.10111002.10EPA 3957958 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564469417.508.10111002.10EPA 3957983 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564471517.508.10111002.08EPA 3957999 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564473517.508.10111002.08EPA 3958009 →
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564508917.508.10111002.08EPA 3958051 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564481517.508.10112002.08EPA 3958079 →
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564483417.508.10111002.08EPA 3958100 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564488517.508.10111002.10EPA 3958130 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564493317.508.10111002.08EPA 3958165 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564495417.508.10111002.10EPA 3958171 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564506017.508.10112002.08EPA 3958249 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21564513317.508.10111002.10EPA 3958286 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →