Keeprite / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 24

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+ furnace: *97CMN0602120B*AHRI reference: 21564948716.008.00111002.05EPA 3997234 →
ESH5X24M12A*+ furnace: *97CMN0601714B*AHRI reference: 21564946616.008.00111002.05EPA 3997248 →
ESH5X24M12A*+ furnace: *96CTN1202422B*AHRI reference: 21564998016.008.00111002.05EPA 3997260 →
ESH5X24M12A*+ furnace: *97VTN1202422A*AHRI reference: 21571307916.008.00111002.05EPA 3997328 →
ESH5X24M12A*+ furnace: *80CTL0902120B*AHRI reference: 21564920516.008.00111002.05EPA 3997337 →
ESH5X24M12A*+ furnace: *97VTN0802120A*AHRI reference: 21571303116.008.00111002.05EPA 3997355 →
ESH5X24M12A*+ furnace: *96VTN0802120B*AHRI reference: 21565013816.008.00111002.05EPA 3997361 →
ESH5X24M12A*+ furnace: *80CTL0901716B*AHRI reference: 21564918416.008.00111002.05EPA 3997370 →
ESH5X24M12A*+ furnace: *80CTL0701716B*AHRI reference: 21564914416.008.00111002.05EPA 3997383 →
ESH5X24M12A*+ furnace: *80CTL0451712B*AHRI reference: 21564910416.008.00111002.05EPA 3997404 →
ESH5X30M12A*+ furnace: *97CMN0602120B*AHRI reference: 21565094616.008.00111002.05EPA 3997413 →
ESH5X30M12A*+ furnace: *96VTN0401410B*AHRI reference: 21565147016.008.00114002.05EPA 3997428 →
ESH5X24M12A*+ furnace: *80MSU0401712A*AHRI reference: 21564899216.007.80110002.05EPA 3997446 →
ESH5X24M12A*+ furnace: *80VSL1352422B*AHRI reference: 21564896816.008.00112002.05EPA 3997462 →
ESH5X30M12A*+ furnace: *97CTN0601716A*AHRI reference: 21571309216.008.00112002.05EPA 3997478 →
ESH5X24M12A*+ furnace: *80VSL0902120B*AHRI reference: 21564893216.008.00111002.05EPA 3997489 →
ESH5X24M12A*+ furnace: *80VSL0901716B*AHRI reference: 21564891316.008.00111002.05EPA 3997502 →
ESH5X30M12A*+ furnace: *97CMN0601714B*AHRI reference: 21565092316.008.00111002.05EPA 3997586 →
ESH5X30M12A*+ furnace: *95MSU0401712A*AHRI reference: 21565120716.008.00111002.05EPA 3997606 →
ESH5X30M12A*+ furnace: *96VSN0401410B*AHRI reference: 21565104916.008.00113002.05EPA 3997623 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →