Keeprite / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 20

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M14A*+ furnace: *96VTN0401410B*AHRI reference: 21564534916.008.00112002.00EPA 3958409 →
EA*5X30M17A*+ furnace: *96VTN0401712B*AHRI reference: 21564602216.008.00112002.05EPA 3958596 →
EA*5X30M17A*+ furnace: *96VSN0401410B*AHRI reference: 21564577316.008.00112002.00EPA 3958795 →
EA*5X30M17A*+ furnace: *96VSN0401712B*AHRI reference: 21564579216.008.10112001.90EPA 3958805 →
EA*5X30M17A*+ furnace: *96VTN0401410B*AHRI reference: 21564599616.008.00112002.00EPA 3958997 →
EA*5X36M17A*+ furnace: *96VSN0401410B*AHRI reference: 21564656216.008.00112002.05EPA 3959264 →
EA*5X36M17A*+ furnace: *96CTN0401410B*AHRI reference: 21564671316.008.00113002.00EPA 3959456 →
EA*5X36M17A*+ furnace: *96VTN0401410B*AHRI reference: 21564678116.008.00112002.00EPA 3959502 →
EA*5X37M17A*+ furnace: *96CTN0401410B*AHRI reference: 21564749916.008.10113002.04EPA 3960210 →
ESH5X24M12A*+ furnace: *80CSU0401712A*AHRI reference: 21564883416.007.80113002.04EPA 3961783 →
ESH5X24M12A*+ furnace: *80VSL0451412B*AHRI reference: 21564885616.007.80110001.94EPA 3961803 →
ESH5X24M12A*+ furnace: *80MSU1002120A*AHRI reference: 21564907816.007.80111002.00EPA 3962072 →
ESH5X24M12A*+ furnace: *80VTL0451412B*AHRI reference: 21564926816.007.80110001.94EPA 3962095 →
ESH5X24M12A*+ furnace: *80VTL0701716B*AHRI reference: 21564931116.007.80111001.92EPA 3962107 →
ESH5X24M12A*+ furnace: *96VSN0601412B*AHRI reference: 21564963216.008.00111002.05EPA 3962136 →
ESH5X24M12A*+ furnace: *96VSN0601716B*AHRI reference: 21564965116.008.00111002.05EPA 3962156 →
ESH5X24M12A*+ furnace: *96VSN0801716B*AHRI reference: 21564967016.007.80110001.94EPA 3962167 →
ESH5X24M12A*+ furnace: *96VSN1002120B*AHRI reference: 21564970716.008.00112002.05EPA 3962185 →
ESH5X24M12A*+ furnace: *96VSN1202422B*AHRI reference: 21564972616.007.80111001.94EPA 3962259 →
ESH5X24M12A*+ furnace: *96VTN0601412B*AHRI reference: 21565005616.008.00111002.05EPA 3962273 →