Keeprite / AIR-SOURCE HEAT PUMP

N5H5S36*K*AAA*

PERFORMANCE 16 SEER2 HP

29 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for N5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1629 / 29
EER2 · BTU/Wh11.7–1329 / 29
HSPF2 · BTU/Wh7.8–829 / 29
Cooling capacity · BTU/h33,800–36,80029 / 29
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,40029 / 29
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80029 / 29
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10029 / 29
COP at 5°F / −15°C2–2.2229 / 29
Equipment / loop typeHP - Split System29 / 29
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)29 / 29
Compressor stagingSingle stage29 / 29
Connected capabilityNo29 / 29

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21705165116.008.00174002.18EPA 4001119 →
FTMA5B48L0C*AHRI reference: 21417995115.507.80167002.18EPA 3404473 →
FEVB0048**+NAVA54801CKAHRI reference: 21417988315.507.80174002.22EPA 3404652 →
FHMA5*48L*C*AHRI reference: 21418019315.507.80174002.18EPA 3404810 →
FMA5X36**AL*AHRI reference: 21442430315.507.80170002.00EPA 3425190 →
F5MA5*48L*C*AHRI reference: 21646401215.507.80174002.18EPA 3846933 →
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21413824315.207.80179002.20EPA 3400373 →
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21414184615.207.80175002.18EPA 3400406 →
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21413998915.207.80180002.20EPA 3400453 →
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21414264515.207.80176002.18EPA 3400574 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21414195815.207.80175002.18EPA 3400625 →
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21414287115.207.80175002.20EPA 3400738 →
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414052615.207.80179002.20EPA 3400800 →
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21414135315.207.80175002.18EPA 3400821 →
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21414138315.207.80176002.20EPA 3400852 →
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414227215.207.80176002.18EPA 3400884 →
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21414146415.207.80175002.18EPA 3400931 →
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 21414306115.207.80181002.14EPA 3400948 →
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413809615.207.80171002.16EPA 3401056 →
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413976815.207.80170002.18EPA 3401106 →