N5H5S36*K*AAA*
PERFORMANCE 16 SEER2 HP
29 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 29 / 29 |
| EER2 · BTU/Wh | 11.7–13 | 29 / 29 |
| HSPF2 · BTU/Wh | 7.8–8 | 29 / 29 |
| Cooling capacity · BTU/h | 33,800–36,800 | 29 / 29 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 29 / 29 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 29 / 29 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 29 / 29 |
| COP at 5°F / −15°C | 2–2.22 | 29 / 29 |
| Equipment / loop type | HP - Split System | 29 / 29 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 29 / 29 |
| Compressor staging | Single stage | 29 / 29 |
| Connected capability | No | 29 / 29 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051651 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001119 → |
FTMA5B48L0C*AHRI reference: 214179951 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404473 → |
FEVB0048**+NAVA54801CKAHRI reference: 214179883 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3404652 → |
FHMA5*48L*C*AHRI reference: 214180193 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404810 → |
FMA5X36**AL*AHRI reference: 214424303 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425190 → |
F5MA5*48L*C*AHRI reference: 216464012 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3846933 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214138243 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400373 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 214141846 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400406 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214139989 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400453 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 214142645 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400574 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 214141958 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400625 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 214142871 | 15.20 | 7.80 | 17500 | 2.20 | EPA 3400738 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 214140526 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400800 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214141353 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400821 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214141383 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400852 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 214142272 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400884 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 214141464 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400931 → |
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 214143061 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3400948 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214138096 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3401056 → |
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 214139768 | 15.20 | 7.80 | 17000 | 2.18 | EPA 3401106 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →