DLCSRBH18AAK
DLC Series · DLC-series · DLCS Series · Dlseries
17 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for DLCSRBH18AAK. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.6–22 | 17 / 17 |
| EER2 · BTU/Wh | 11.7–13 | 17 / 17 |
| HSPF2 · BTU/Wh | 9.5–11.3 | 17 / 17 |
| Cooling capacity · BTU/h | 16,000–18,000 | 17 / 17 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,000–20,000 | 17 / 17 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 11,100–15,800 | 17 / 17 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,000–18,000 | 17 / 17 |
| COP at 5°F / −15°C | 1.75–2.2 | 17 / 17 |
| Equipment / loop type | HP - Mini or Multi Split · HP - Split System | 17 / 17 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 17 / 17 |
| Compressor staging | Continuously variable | 17 / 17 |
| Connected capability | No | 17 / 17 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
DLFSHBH18XAKCold climate designationAHRI reference: 206361891 | 22.00 | 10.60 | 17200 | 1.89 | EPA 2410576 → |
DLFSHCH18XAKCold climate designationAHRI reference: 208447651 | 21.50 | 11.30 | 18000 | 1.80 | EPA 2410819 → |
DHMAHBQ18XA3Cold climate designationAHRI reference: 216091515 | 21.50 | 11.30 | 18000 | 1.80 | EPA 3799108 → |
DLFSFAH18XAKCold climate designationAHRI reference: 206350433 | 20.50 | 9.80 | 16800 | 1.86 | EPA 2410386 → |
40MBFQ18---3Cold climate designationAHRI reference: 216091645 | 20.50 | 9.80 | 16800 | 1.86 | EPA 3799156 → |
DLFSCAH18XAKCold climate designationAHRI reference: 206350431 | 20.00 | 9.50 | 16000 | 1.75 | EPA 2410388 → |
40MBCQ18---3Cold climate designationAHRI reference: 216091630 | 20.00 | 9.50 | 16000 | 1.75 | EPA 3799148 → |
DLFSOAH18XAKCold climate designationAHRI reference: 210857443 | 19.80 | 11.20 | 16700 | 1.93 | EPA 2410969 → |
DLFCCAH18XAKCold climate designationAHRI reference: 209270264 | 19.80 | 11.20 | 16700 | 1.93 | EPA 2411059 → |
40MCCAQ18XA3Cold climate designationAHRI reference: 216091681 | 19.80 | 11.20 | 16700 | 1.93 | EPA 3799173 → |
DLFSDAH18XAKCold climate designationAHRI reference: 206350432 | 18.00 | 9.50 | 17700 | 1.85 | EPA 2410387 → |
DLFSDAH24XAKCold climate designationAHRI reference: 207801572 | 18.00 | 10.50 | 16000 | 2.00 | EPA 2410717 → |
DLFSDAH18XHKCold climate designationAHRI reference: 211132691 | 18.00 | 10.80 | 18000 | 2.20 | EPA 2410925 → |
40MBDQ18---3Cold climate designationAHRI reference: 216091661 | 18.00 | 9.50 | 17700 | 1.85 | EPA 3799166 → |
40MBDAQ18XH3Cold climate designationAHRI reference: 216091672 | 18.00 | 10.80 | 18000 | 2.20 | EPA 3799178 → |
DLFSABH18XBKCold climate designationAHRI reference: 207826603 | 17.60 | 9.60 | 17000 | 2.00 | EPA 2460121 → |
40MBABQ18XB3Cold climate designationAHRI reference: 216091291 | 17.60 | 9.60 | 17000 | 2.00 | EPA 3848978 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →