D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 6
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X42M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 218493694 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636596 → |
EA*5X42M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218493680 | 16.00 | 8.50 | 31000 | 1.80 | EPA 4636610 → |
EA*5X42M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218493624 | 16.00 | 8.50 | 30800 | 1.80 | EPA 4636652 → |
EA*5X42M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218493611 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636660 → |
EA*5X42M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 218493559 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636705 → |
EA*5X42M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218493545 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636716 → |
EA*5X42M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218493518 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636730 → |
EA*5X42M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218493505 | 16.00 | 8.10 | 30800 | 1.75 | EPA 4636737 → |
EA*5X42M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218493491 | 16.00 | 8.50 | 31000 | 1.80 | EPA 4636749 → |
EA*5X43M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218493410 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4636799 → |
EA*5X43M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218493396 | 16.00 | 8.50 | 30400 | 1.84 | EPA 4636811 → |
EA*5X43M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218493382 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636823 → |
EA*5X43M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218493342 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4636855 → |
EA*5X43M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218493333 | 16.00 | 8.50 | 30400 | 1.84 | EPA 4636864 → |
EA*5X43M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218493326 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636871 → |
EA*5X43M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218493298 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636892 → |
EA*5X43M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218493284 | 16.00 | 8.50 | 30400 | 1.84 | EPA 4636906 → |
EA*5X43M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 218493270 | 16.00 | 8.50 | 30200 | 1.84 | EPA 4636920 → |
EA*5X43M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218493263 | 16.00 | 8.50 | 30400 | 1.84 | EPA 4636927 → |
EA*5X43M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218493256 | 16.00 | 8.50 | 30400 | 1.86 | EPA 4636934 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.