D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 12
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X42M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218493666 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636622 → |
EA*5X42M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218493652 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636633 → |
EA*5X42M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218493598 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636669 → |
EA*5X42M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218493585 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636681 → |
EA*5X43M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 218493465 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636763 → |
EA*5X43M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218493368 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636834 → |
EA*5X43M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218493319 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636878 → |
EA*5X43M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218493277 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636913 → |
EA*5X43M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218493249 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636941 → |
EA*5X48M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218496367 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4637450 → |
EA*5X43M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218496360 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4637457 → |
EA*5X42M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218496353 | 15.50 | 8.50 | 30800 | 1.80 | EPA 4637464 → |
EA*5X37M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218496346 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4637471 → |
EA*5X43M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218496318 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4637478 → |
EA*5X42M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218496311 | 15.50 | 8.50 | 30800 | 1.78 | EPA 4637485 → |
EA*5X37M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218496304 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4637492 → |
EA*5X43M21A*+ furnace: *96MSN0802120A*Cold climate designationAHRI reference: 218496265 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637507 → |
EA*5X37M21A*+ furnace: *96MSN0802120A*Cold climate designationAHRI reference: 218496249 | 15.50 | 8.50 | 30200 | 1.84 | EPA 4637523 → |
EA*5X48M21A*+ furnace: *92MSN1002122A*Cold climate designationAHRI reference: 218496087 | 15.50 | 8.50 | 30000 | 1.82 | EPA 4637531 → |
EA*5X43M21A*+ furnace: *92MSN1002122A*Cold climate designationAHRI reference: 218496080 | 15.50 | 8.50 | 30200 | 1.82 | EPA 4637538 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →