D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 19
499 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X30M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218487990 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4632956 → |
ESH5X30M12A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218487976 | 16.00 | 8.50 | 19500 | 1.90 | EPA 4632970 → |
ESH5X30M12A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218487969 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4632977 → |
ESH5X30M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 218487962 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4632984 → |
ESH5X30M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 218487955 | 16.00 | 8.50 | 19700 | 1.90 | EPA 4632991 → |
ESH5X30M12A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218487948 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4632998 → |
ESH5X30M12A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218487941 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4633005 → |
ESH5X30M12A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218487934 | 16.00 | 8.50 | 19600 | 1.90 | EPA 4633012 → |
EA*5X24M14A*+ furnace: *96MSN0261410A*Cold climate designationAHRI reference: 218484660 | 15.50 | 8.50 | 19800 | 1.92 | EPA 4629154 → |
EA*5X24M17A*+ furnace: *96MSN0261410A*Cold climate designationAHRI reference: 218484758 | 15.50 | 8.50 | 19800 | 1.92 | EPA 4629271 → |
EA*5X24M17A*+ furnace: *96MSN0601716A*Cold climate designationAHRI reference: 218484788 | 15.50 | 8.50 | 20000 | 1.92 | EPA 4629364 → |
EA*5X37M17A*+ furnace: *96MSN0401410A*Cold climate designationAHRI reference: 218485298 | 15.50 | 8.50 | 19200 | 1.96 | EPA 4629451 → |
EA*5X30M14A*+ furnace: *96MSN0261410A*Cold climate designationAHRI reference: 218484951 | 15.50 | 8.50 | 19600 | 1.92 | EPA 4629790 → |
EA*5X25M17A*+ furnace: *96MSN0401410A*Cold climate designationAHRI reference: 218484886 | 15.50 | 8.50 | 19100 | 1.96 | EPA 4629840 → |
ESH5X30M12A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218485915 | 15.50 | 8.50 | 19600 | 1.92 | EPA 4629894 → |
ESH5X30M12A*+ furnace: *80MS(N,L)1552420A*Cold climate designationAHRI reference: 218485808 | 15.50 | 8.50 | 19600 | 1.94 | EPA 4629972 → |
ESH5X30M12A*+ furnace: *80MS(N,L)0902420A*Cold climate designationAHRI reference: 218485780 | 15.50 | 8.50 | 19500 | 1.94 | EPA 4630000 → |
ESH5X30M12A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 218487913 | 15.50 | 8.50 | 19600 | 1.90 | EPA 4630324 → |
ESH5X30M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 218487850 | 15.50 | 8.50 | 19700 | 1.92 | EPA 4630387 → |
ESH5X30M12A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218487836 | 15.50 | 8.50 | 19700 | 1.92 | EPA 4630401 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →