Keeprite / AIR-SOURCE HEAT PUMP

C5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.585 / 85
EER2 · BTU/Wh11.7–1385 / 85
HSPF2 · BTU/Wh7.8–8.585 / 85
Cooling capacity · BTU/h54,000–58,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50085 / 85
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80085 / 85
COP at 5°F / −15°C2.18–2.3685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21634694716.008.10304002.24EPA 3805337 →
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634696316.008.10304002.26EPA 3805353 →
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21634623516.008.10302002.24EPA 3805525 →
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634627516.008.10300002.26EPA 3805534 →
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21634775516.008.50316002.34EPA 3805653 →
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21634849916.007.80304002.20EPA 3805725 →
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21634850716.007.80302002.20EPA 3805733 →
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21634852316.007.80302002.20EPA 3805741 →
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21634701116.008.10304002.24EPA 3805856 →
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634867516.007.80300002.20EPA 3806015 →
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634713116.008.10302002.24EPA 3806077 →
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634810716.007.80298002.22EPA 3806749 →
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21634811516.007.80298002.22EPA 3806758 →
EA*5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21634881116.007.80302002.22EPA 3806768 →
EA*5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634881916.007.80302002.22EPA 3806776 →
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21634882716.007.80300002.20EPA 3806783 →
EA*5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21634883516.007.80302002.22EPA 3806791 →
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21634884316.007.80302002.20EPA 3806800 →
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634803516.007.80298002.22EPA 3806823 →
EA*5X60M24A*+ furnace: *80VSL1102122B*AHRI reference: 21634804316.007.80298002.22EPA 3806831 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →