Keeprite / AIR-SOURCE HEAT PUMP

C5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 6

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for C5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X49M24A*+ furnace: *80VTL0902120B*AHRI reference: 21635058717.008.10250002.12EPA 3803876
EVD5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21635136417.008.10256002.12EPA 3803912
EVD5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21635137217.008.10254002.12EPA 3803921
EVD5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21635138017.008.50252002.24EPA 3803929
EVD5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21635139617.008.10252002.14EPA 3803945
EVD5X61M24A*+ furnace: *96VTN1002120B*AHRI reference: 21635144417.008.10252002.14EPA 3803966
EVD5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21635126817.008.50250002.26EPA 3803988
EVD5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 21635128417.008.50250002.28EPA 3804083
EA*5X61M24A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635291617.008.00248002.26EPA 3804145
EVM5X49M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634992317.008.10244002.18EPA 3804195
EVD5X49M24A*+ furnace: *96VTN1002122B*AHRI reference: 21635069117.008.50248002.26EPA 3805238
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21635077917.008.10248002.16EPA 3805244
EVM5X49M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21634994717.008.00238002.18EPA 3805267
EVM5X49M21A*+ furnace: *97VTN1002122A*AHRI reference: 21634997917.008.00244002.14EPA 3805398
EVM5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21634999517.008.10246002.14EPA 3805414
EVM5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21635000317.008.10244002.16EPA 3805422
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635001117.008.10250002.14EPA 3805429
EVD5X49M24A*+ furnace: *97VTN1002122A*AHRI reference: 21635073117.008.00248002.12EPA 3805467
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635076317.008.10250002.14EPA 3805473
EVD5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21635074717.008.10246002.16EPA 3805497

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →