Keeprite / AIR-SOURCE HEAT PUMP

C5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 4

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for C5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635096317.508.00238002.18EPA 3806168
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635097117.508.00236002.16EPA 3806176
FCMA5B60L0D*+WALLCONAHRI reference: 21635400417.508.00246002.32EPA 3806330
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635022717.508.00236002.16EPA 3806397
EVM5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21635025117.508.00244002.14EPA 3806426
EVD5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21635099517.508.00244002.14EPA 3806462
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635102717.508.10250002.14EPA 3806468
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635103517.508.50244002.30EPA 3806476
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21635101917.508.50248002.26EPA 3806500
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635108317.508.10246002.16EPA 3807005
EVD5X61M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635109117.508.00238002.16EPA 3807013
EVD5X61M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21635110017.508.00236002.18EPA 3807021
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21634973117.508.00252002.10EPA 3807114
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634976317.508.10244002.16EPA 3807146
EVD5X61M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635118017.508.00236002.18EPA 3807189
EVD5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21635132417.508.50248002.28EPA 3807209
EVD5X61M24A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635133217.508.00238002.18EPA 3807217
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635120417.508.50246002.28EPA 3807223
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21635104317.508.50250002.26EPA 3807336
EVM5X60M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635010717.508.00236002.16EPA 3807445

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →