Keeprite / AIR-SOURCE HEAT PUMP

C5H8T36*K*AAA*

Mainline 18 SEER2 HP · source records, page 7

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5188 / 188
EER2 · BTU/Wh11.7–13188 / 188
HSPF2 · BTU/Wh7.8–8.5188 / 188
Cooling capacity · BTU/h33,800–38,000188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200188 / 188
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600188 / 188
COP at 5°F / −15°C1.84–2.4188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingTwo-stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635458815.207.80178001.86EPA 3807572 →
EVM5X48M21A*+ furnace: *96VTN0802120B*AHRI reference: 21635462015.207.80179001.86EPA 3807580 →
EA*5X48M21A*+ furnace: *80VSL0701716B*AHRI reference: 21635866015.208.10192002.26EPA 3807614 →
EA*5X48M21A*+ furnace: *80VSL0901716B*AHRI reference: 21635866815.208.10191002.28EPA 3807622 →
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21635570015.207.80179001.86EPA 3807682 →
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21635574015.207.80179001.86EPA 3807706 →
ESH5X48M12A*+ furnace: *80MSU0601716A*AHRI reference: 21636016415.208.10190002.28EPA 3807730 →
ESH5X48M12A*+ furnace: *80MSU0802120A*AHRI reference: 21636017215.208.10190002.30EPA 3807738 →
ESH5X48M12A*+ furnace: *80MSU1002120A*AHRI reference: 21636018015.207.80190002.22EPA 3807746 →
EA*5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21635722015.208.10194002.28EPA 3807762 →
EA*5X42M21A*+ furnace: *95MSU1002122A*AHRI reference: 21635795615.208.10188002.26EPA 3807809 →
EA*5X42M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635792415.208.10190002.26EPA 3807817 →
EA*5X42M21A*+ furnace: *95MSU1002120A*AHRI reference: 21635794815.208.10188002.28EPA 3807823 →
ESH5X42M12A*+ furnace: *80VSL0902120B*AHRI reference: 21635962015.207.80191002.20EPA 3807830 →
ESH5X42M12A*+ furnace: *80VSL1102122B*AHRI reference: 21635962815.207.80190002.20EPA 3807838 →
ESH5X48M12A*+ furnace: *80VTL0902120B*AHRI reference: 21636025215.208.10192002.26EPA 3807849 →
EA*5X37M21A*+ furnace: *80VTL0701716B*AHRI reference: 21635733215.208.10194002.28EPA 3807902 →
EA*5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635887615.208.10192002.26EPA 3807974 →
EA*5X48M21A*+ furnace: *80VTL0701716B*AHRI reference: 21635877215.208.10193002.26EPA 3808004 →
ESH5X42M12A*+ furnace: *80MSU0601716A*AHRI reference: 21635965215.207.80190002.22EPA 3808026 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →