Keeprite / AIR-SOURCE HEAT PUMP

C5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 6

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 21636649317.508.10112002.12EPA 3810874
EA*5X25M17A*+WALLCON+ furnace: *80CTL0701716B*AHRI reference: 21636497217.508.00112002.08EPA 3810915
EA*5X25M17A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21636498017.508.00112002.08EPA 3810923
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21636498817.508.10110002.12EPA 3810931
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21636499617.508.10111002.12EPA 3810939
EA*5X37M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21636640517.508.10113002.10EPA 3810996
EA*5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21636641317.508.10111002.12EPA 3811004
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21636642917.508.10111002.12EPA 3811020
EA*5X37M17A*+WALLCON+ furnace: *96CTN0801714B*AHRI reference: 21636626917.508.00112002.08EPA 3811128
EA*5X37M17A*+ furnace: *96VTN0801716B*AHRI reference: 21636630917.508.10111002.10EPA 3811168
EA*5X36M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636564417.508.10109002.10EPA 3811505
EA*5X36M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636565217.508.10110002.08EPA 3811513
EA*5X36M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636566817.507.80109002.02EPA 3811529
EA*5X36M17A*+ furnace: *80MSU0601716A*AHRI reference: 21636567617.507.80109002.04EPA 3811537
EA*5X37M21A*+WALLCON+ furnace: *97CMN0602120B*AHRI reference: 21636658117.508.10113002.10EPA 3811647
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636505217.508.10112002.10EPA 3811679
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21636515617.508.10111002.12EPA 3812072
EA*5X25M17A*+ furnace: OMV112K14AAHRI reference: 21636516417.508.10115002.06EPA 3812080
EA*5X25M17A*+WALLCON+ furnace: *95CSU0601716B*AHRI reference: 21636500417.508.00112002.08EPA 3812124
EA*5X25M17A*+WALLCON+ furnace: *97CMN0601714B*AHRI reference: 21636501217.508.00113002.08EPA 3812132

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →