C5H6S19*K*AAA*
MAINLINE 16 SEER2 HP · source records, page 4
76 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H6S19*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 76 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 76 / 76 |
| EER2 · BTU/Wh | 12.5–13 | 76 / 76 |
| HSPF2 · BTU/Wh | 7.8–8 | 76 / 76 |
| Cooling capacity · BTU/h | 17,700–19,300 | 76 / 76 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,400–19,500 | 76 / 76 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,300–11,000 | 76 / 76 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 76 / 76 |
| COP at 5°F / −15°C | 1.9–2 | 76 / 76 |
| Equipment / loop type | HP - Split System | 76 / 76 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 76 / 76 |
| Compressor staging | Single stage | 76 / 76 |
| Connected capability | No | 76 / 76 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X19M17A*+ furnace: *96MSN0601412A*AHRI reference: 217721659 | 15.50 | 8.00 | 8400 | 1.98 | EPA 4509697 → |
EA*5X19M17A*+ furnace: *96VTN0601716B*AHRI reference: 217721804 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509709 → |
EA*5X19M17A*+ furnace: *96VTN0801716B*AHRI reference: 217721812 | 15.50 | 8.00 | 8300 | 2.00 | EPA 4509717 → |
EA*5X19M17A*+ furnace: *97VTN0601716A*AHRI reference: 217721820 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509725 → |
EA*5X19M17A*+ furnace: *97VTN0801716A*AHRI reference: 217721828 | 15.50 | 8.00 | 8300 | 2.00 | EPA 4509733 → |
EA*5X25M17A*+WALLCON+ furnace: *95CSU0601716B*AHRI reference: 217722589 | 15.50 | 7.80 | 8400 | 1.90 | EPA 4509737 → |
EA*5X25M17A*+WALLCON+ furnace: *97CMN0601714B*AHRI reference: 217722597 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509745 → |
EA*5X25M17A*+ furnace: *96MSN0261410A*AHRI reference: 217722645 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509785 → |
EA*5X25M17A*+ furnace: *96MSN0601412A*AHRI reference: 217722670 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509806 → |
EA*5X25M17A*+ furnace: *96MSN0801716A*AHRI reference: 217722678 | 15.50 | 8.00 | 8500 | 2.00 | EPA 4509814 → |
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 217722702 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509822 → |
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 217722710 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4509830 → |
EA*5X25M17A*+ furnace: *95MSU0401712A*AHRI reference: 217722718 | 15.50 | 7.80 | 8400 | 1.90 | EPA 4509838 → |
FHMA5*18L*A*AHRI reference: 217687320 | 15.20 | 7.80 | 8100 | 1.90 | EPA 4506521 → |
FMA5L18**AL*AHRI reference: 217726367 | 15.20 | 7.80 | 8400 | 1.95 | EPA 4509267 → |
F5MA5*18L*A*AHRI reference: 217726310 | 15.20 | 7.80 | 8100 | 1.90 | EPA 4509285 → |