C5H3V36*K*AAA*
ProComfort 23 VS HP · source records, page 7
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 541 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.14 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X49M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215935101 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3724529 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215935111 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3724539 → |
EVD5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215936791 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3724807 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 215931502 | 21.50 | 9.50 | 25800 | 2.06 | EPA 3725122 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215936901 | 21.50 | 8.50 | 28600 | 1.98 | EPA 3725201 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215936911 | 21.50 | 8.50 | 28800 | 2.04 | EPA 3725269 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215936921 | 21.50 | 8.50 | 28200 | 2.00 | EPA 3725279 → |
EVM5X44M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215934801 | 21.50 | 8.50 | 28800 | 2.02 | EPA 3725287 → |
EVM5X44M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215934821 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725307 → |
EVM5X44M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215934831 | 21.50 | 8.50 | 28600 | 2.02 | EPA 3725317 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215936311 | 21.50 | 8.50 | 28400 | 2.04 | EPA 3725341 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215936321 | 21.50 | 8.50 | 28200 | 2.04 | EPA 3725351 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215936331 | 21.50 | 8.50 | 28200 | 2.04 | EPA 3725361 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215936341 | 21.50 | 8.50 | 28200 | 2.04 | EPA 3725371 → |
EVD5X48M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215936361 | 21.50 | 8.50 | 28200 | 2.04 | EPA 3725391 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215935191 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725681 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215935201 | 21.50 | 8.50 | 28600 | 2.02 | EPA 3725691 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215935241 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725739 → |
EVD5X38M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215935861 | 21.50 | 8.50 | 28800 | 2.02 | EPA 3725798 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215935251 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3725918 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.